YFB4 Series Dust Ignition-Proof Three-Phase Asynchronous Motor (YFB4-180L-4 22kW)
GORNOVENT YFB4 Series Dust Explosion-Proof Motors (featured configuration: YFB4-180L-4-22KW) are specialized, totally enclosed fan-cooled (TEFC) three-phase squirrel-cage asynchronous motors engineered for hazardous locations where combustible dust clouds or dust layers are present. Featuring a high-integrity IP65 dust-tight cast-iron enclosure, the motor prevents explosive dust ingress and strictly limits maximum external surface temperature so surrounding explosive dust mixtures are never ignited.
Designed and tested in strict accordance with GB 12476.1-2013 & GB 12476.5-2013 (equivalent to IEC 61241-1 / IEC 60079-31 Ex tD / Ex tb) and mandatory CNCA-C23-01 / JExMC-XZ-C23-2020 explosion-protection certification rules, the YFB4 series provides reliable prime mover power for industrial centrifugal fans, axial mine ventilators, conveyors, and process machinery in coal mines, petrochemical plants, and grain or metal processing facilities.
IP65 Dust-Tight Enclosure
Temp Class T4 (≤ 135°C Surface Limit)
IEC 60079-31 / GB 12476 Certified
Precision-machined spigot joints, shaft labyrinth seals, and conductive rubber gaskets achieve IP6X (IP65) dust-tight protection—completely preventing combustible dust from entering the motor housing.
Low-loss silicon steel laminations and 100% pure copper windings ensure that under both dust-free and dust-blanketed test conditions, the maximum external surface temperature never exceeds 135°C (Group T4).
Manufactured in compliance with GB 12476.1-2013, GB 12476.5-2013 (IEC 60079-31), CNCA-C23-01, and JExMC-XZ-C23-2020 mandatory explosion-proof certification rules under ISO 9001 quality control.
High-strength HT250 cast-iron frame with anti-static external cooling fan and Class F/H vacuum-pressure-impregnated (VPI) copper stator coils for continuous S1 industrial duty.
YFB4-180L-4-22KW Technical Datasheet & Series Range
Detailed electrical and mechanical parameters for order code YFB4-180L-4-22KW, alongside representative 4-pole frame sizes in the YFB4 dust explosion-proof series.
| Order Code / Model | Rated Power (kW) | Poles | Rated Speed (r/min) | Rated Voltage (V) | Enclosure Rating | Max Surface Temp | Shaft Height (mm) |
|---|---|---|---|---|---|---|---|
| YFB4-132S-4-5.5KW | 5.5 | 4P | 1455 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 132 |
| YFB4-132M-4-7.5KW | 7.5 | 4P | 1460 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 132 |
| YFB4-160M-4-11KW | 11.0 | 4P | 1470 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 160 |
| YFB4-160L-4-15KW | 15.0 | 4P | 1475 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 160 |
| YFB4-180M-4-18.5KW | 18.5 | 4P | 1480 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 180 |
| YFB4-180L-4-22KW (Featured) | 22.0 | 4P | 1485 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 180 |
| YFB4-200L-4-30KW | 30.0 | 4P | 1485 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 200 |
| YFB4-225S-4-37KW | 37.0 | 4P | 1485 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 225 |
| YFB4-225M-4-45KW | 45.0 | 4P | 1485 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 225 |
| YFB4-250M-4-55KW | 55.0 | 4P | 1485 | 380V (50Hz) | IP65 | T4 (≤ 135°C) | 250 |
YFB4-180L-4-22KW Complete Specification Matrix
Where Are YFB4 Dust Explosion-Proof Motors Used?
Drives ventilation fans, belt conveyors, and dust collectors in coal preparation plants, surface mining transfer stations, and high-dust mineral processing tunnels.
Safe operation in Zone 21 and Zone 22 petrochemical processing units handling combustible polymer powders, sulfur dust, synthetic resins, and chemical pigments.
Prevents dust cloud ignition in agricultural grain elevators, starch processing lines, sugar refineries, and pneumatic conveying blowers where organic dust accumulates.
Engineered with IP65 dust-tight sealing to exclude conductive metal dust (aluminum/magnesium polishing) and combustible wood flour or textile fibers.
How to Select a Dust Ignition-Proof Motor
Frequently Asked Questions
How does a YFB4 dust explosion-proof motor prevent dust explosions?
The YFB4 motor utilizes two primary protection principles (Ex tD / Ex tb): first, its high-seal IP65 dust-tight enclosure prevents combustible dust from entering the internal stator/rotor cavity; second, its thermal design limits the external casing surface temperature to ≤ 135°C (Class T4) even under a surface dust layer, preventing thermal ignition of surrounding dust clouds.
What standards and certifications does the YFB4 series comply with?
The YFB4 series is engineered and tested in compliance with national standards GB 12476.1-2013 and GB 12476.5-2013 (aligned with international IEC 61241-1 / IEC 60079-31 standards), and satisfies mandatory explosion-proof certification rules CNCA-C23-01 and JExMC-XZ-C23-2020 under an ISO 9001 quality system.
What is the difference between Dust-Tight (IP6X) and Dust-Protected (IP5X) enclosures?
Dust-Tight (IP6X / IP65) enclosures prevent any observable ingress of dust under negative-pressure testing and are suitable for high-risk Zone 21 and conductive dust environments. Dust-Protected (IP5X / IP55) enclosures do not completely prevent dust entry, but restrict ingress to a level that cannot impair safe motor operation in Zone 22 areas. GORNOVENT YFB4-180L-4 motors feature full IP65 protection.
Can the YFB4-180L-4 22kW motor be used as a replacement motor for industrial fans?
Yes. With standard IEC frame dimensions (180mm shaft center height, 4-pole 1485 r/min) and available B3, B5, or B35 mounting flanges, the YFB4-180L-4-22KW can directly drive GORNOVENT centrifugal fans (such as 4-72 / B4-72 No. 8D/8C/10C) and axial ventilators operating in dusty hazardous plants.