SDS Jet Fans for Tunnel Ventilation and Smoke Extraction

GORNOVENT SDS Series Axial Jet Fans are engineered for ductless longitudinal ventilation, pollutant dilution, and emergency smoke extraction in road, rail, and metro tunnels.

Certified Thrust50 N – 3,050 N
Impeller Diameter400 – 1,800 mm
Fire Smoke RatingEN 12101-3 F300 / F400
Airflow DirectionUnidirectional / 100% Reversible
✓ISO 13350 Verified Performance: Airflow from 7,560 to 300,960 m³/h with motor power up to 90 kW (380V / 660V / 1,140V).
✓Low-Noise & Anti-Corrosion Build: X-ray inspected cast aluminium blades (G2.5 balanced), tubular acoustic silencers, and hot-dip galvanized or C5-M coated casings.
✓Life-Safety Compliant: Dual-purpose continuous ventilation and 300°C/400°C (2-hour) emergency fire smoke control per NFPA 502 & NFPA 130.
Engineering Support: Contact us with your tunnel cross-section and target thrust for a custom selection schedule, ISO performance curves, and 3D CAD / BIM submittals.
GORNOVENT Tunnel Ventilation Systems

SDS Series Axial Jet Fans for Tunnel Ventilation & Smoke Extraction

GORNOVENT SDS Jet Fans are heavy-duty axial impulse fans engineered for longitudinal air movement, pollutant dilution, and emergency smoke control in road tunnels, metro rail networks, and underground caverns. By transferring high-velocity discharge momentum directly to the tunnel air column, the SDS series eliminates the need for costly continuous ductwork.

Available in rotor diameters from 400 mm (SDS-40) to 1,800 mm (SDS-180), the series delivers certified thrust forces from 50 N up to 3,050 N in both unidirectional and 100% truly reversible configurations.

ISO 13350 Thrust Tested
EN 12101-3 Smoke Rated (F300 / F400)
NFPA 502 / NFPA 130 Compliant
ISO 1940-1 G2.5 Balanced
Ductless Impulse Thrust

Generates longitudinal airflow across the entire tunnel cross-section, drastically reducing civil excavation and installation overhead.

100% Reversible Airflow

Symmetrical aerofoil impellers provide identical 1:1 thrust in forward and reverse directions for rapid emergency smoke redirection.

High-Temp Fire Rated

Engineered for continuous daily pollutant dilution and certified high-temperature smoke extraction during tunnel fire emergencies.

Aerodynamic Performance

SDS Series Technical Parameters

Reference performance data measured in accordance with ISO 13350. Final operating point, blade pitch angle, and acoustic attenuation are configured to project specifications.

Model Thrust Range (N) Airflow (m³/h) Motor Power (kW) Noise Lp @ 3m (dB(A))
SDS-40 50 – 115 7,560 – 11,520 0.75 – 2.2 64 – 68
SDS-50 130 – 285 15,120 – 23,400 2.2 – 7.5 64 – 68
SDS-56 200 – 385 22,320 – 30,960 4.0 – 11.0 64 – 68
SDS-63 247 – 602 29,160 – 45,720 7.5 – 18.5 64 – 70
SDS-71 475 – 960 45,720 – 64,800 15.0 – 37.0 67 – 73
SDS-80 204 – 461 33,480 – 50,760 4.0 – 11.0 56 – 63
SDS-90 313 – 744 46,800 – 72,360 7.5 – 18.5 60 – 67
SDS-100 466 – 1,076 63,720 – 96,840 11.0 – 30.0 63 – 70
SDS-112 744 – 1,691 89,280 – 134,640 18.5 – 55.0 68 – 73
SDS-125 1,185 – 2,574 126,000 – 185,400 37.0 – 90.0 72 – 78
SDS-140 870 – 1,898 120,960 – 178,560 18.5 – 55.0 64 – 69
SDS-160 1,320 – 3,046 169,920 – 258,480 30.0 – 90.0 68 – 75
SDS-180 1,575 – 3,050 216,720 – 300,960 30.0 – 75.0 69 – 75
* Free-field sound pressure levels (Lp) are measured at 3 meters at a 45° angle. Custom 1D or 2D silencer pods can be specified for stricter acoustic limits.
Mechanical Engineering

Construction & Component Features

X-Ray Inspected Cast Aluminium Impeller

Precision-cast corrosion-resistant aluminium alloy blades, X-ray inspected for structural integrity and dynamically balanced to ISO 1940-1 Grade G2.5.

Aerodynamic Acoustic Silencers

Tubular inlet and outlet attenuators packed with non-combustible, glass-cloth-lined mineral wool and retained by perforated galvanized or stainless steel sheet.

Heavy-Gauge Casing & Drop Mounts

Spun flanged steel casing protected by hot-dip galvanization (EN ISO 1461) or C4/C5 marine epoxy coatings, complete with pre-engineered ceiling suspension brackets.

Tunnel-Duty Asynchronous Motors

IP55/IP65 TEFC motors with Class H insulation, available in single-speed, two-speed (Dahlander), or VFD-driven designs for SCADA integration.

Project Customization

Technical Configuration Matrix

Configuration TypeUnidirectional or 100% Reversible
Thrust Test StandardISO 13350 Certified
Smoke Rating (EN 12101-3)F300 (300°C/2h) / F400 (400°C/2h)
Power Supply Options380V / 400V / 660V / 1,140V (50/60Hz)
Ingress & InsulationIP55 or IP65 / Class H Insulation
Vibration Severity< 2.8 mm/s RMS (ISO 14694 BV-3)
Corrosion ProtectionHot-Dip Galvanized / AISI 316L / C5 Coating
Explosion Proof OptionATEX / IECEx Flameproof Available
Installation Clearances

Outline Dimensions & Mounting (mm)

Preliminary dimensional envelope for tunnel soffit clearance planning. Request certified model-specific general arrangement (GA) drawings prior to civil anchor installation.

GORNOVENT SDS jet fan dimensional drawing showing length A, diameter B, and mounting brackets C D E H

Key Dimensions: A = Overall Length | B = Outer Silencer Diameter | C, D, E = Suspension Bracket Centres | H = Total Installed Height
Model A (Length) B (Dia) C (Mount L) D (Inner Ø) E (Mount W) H (Height)
SDS-40 2,030 800 570 560 660 760
SDS-50 2,480 1,000 650 660 750 860
SDS-56 2,820 1,120 750 720 800 920
SDS-63 3,190 1,260 750 800 940 1,100
SDS-71 3,510 1,420 800 900 1,020 1,200
SDS-80 2,300 800 840 1,000 1,100 1,300
SDS-90 3,130 1,215 940 1,100 1,180 1,400
SDS-100 3,180 1,215 1,000 1,200 1,260 1,500
SDS-112 3,380 1,265 1,100 1,320 1,360 1,620
SDS-125 3,350 1,250 1,160 1,450 1,470 1,750
SDS-140 3,850 1,400 1,160 1,700 1,740 2,100
SDS-160 4,300 1,600 1,360 1,900 1,880 2,300
SDS-180 4,700 1,800 1,500 2,100 2,050 2,500
Engineering Guide

5-Step Tunnel Jet Fan Selection Workflow

01
Calculate Tunnel Aerodynamic ResistanceProvide tunnel length, hydraulic diameter, longitudinal gradient, vehicle traffic drag, and portal wind pressures.
02
Determine Effective Installed Thrust (N)Select fan units based on net thrust after accounting for wall installation efficiency (Coanda effect) and velocity profile losses.
03
Verify Fire & Reversibility RequirementsSpecify unidirectional or 100% reversible blades and confirm the emergency temperature/duration rating (e.g., 300°C or 400°C for 2 hours).
04
Define Electrical & Starting MethodConfirm tunnel supply voltage, starting current limitations (DOL, Soft Starter, or VFD), and dual-speed operation modes.
05
Confirm Envelope & Acoustic LimitsCheck overall height (H) against the tunnel kinematic clearance gauge and verify sound pressure limits at portal boundaries.
Knowledge Base

Frequently Asked Questions

What is an SDS jet fan and how does it ventilate a tunnel without ducts?

An SDS jet fan is an axial impulse fan suspended from the tunnel soffit. It intakes a portion of the tunnel air and discharges it at high velocity. Through momentum transfer, this high-speed air jet entrains the surrounding air mass and drives longitudinal airflow along the entire tunnel length.

Do reversible SDS jet fans lose thrust when running in reverse?

No. When specified with symmetrical aerofoil impellers, GORNOVENT SDS jet fans achieve 100% true reversibility—delivering identical aerodynamic thrust and airflow in both forward and reverse directions.

Can SDS jet fans be used for high-temperature fire smoke extraction?

Yes. Dual-purpose SDS jet fans are engineered and tested in compliance with EN 12101-3 standards, including Class F300 (300°C for 120 minutes) and Class F400 (400°C for 120 minutes), satisfying NFPA 502 and NFPA 130 life-safety codes.

Are BIM / 3D CAD models and performance curves available for tunnel simulation?

Yes. We provide complete engineering submittals including ISO 13350 thrust curves, acoustic octave band data, and 3D CAD/Revit (.dwg / .step / .rfa) models for tunnel clash detection and CFD modeling.

Request Project Sizing & Engineering Submittals

Send us your tunnel geometry, target thrust schedule, and fire-rating specifications. Our ventilation engineers will prepare a complete technical proposal, fan curve submittal, and quotation.