,

Portable Explosion-Proof Axial Fan (Ex d IIB T4 Confined Space Ventilator, 200–500mm)

GORNOVENT Portable Explosion-Proof Axial Fans (Models 200 to 500) are compact, high-static-pressure portable ventilators designed for volatile gas extraction, fume purging, and fresh air supply in confined spaces, tanks, manholes, and hazardous industrial zones.

Airflow Capacity1,500 – 10,000 m³/h
Static Pressure185 – 800 Pa
Explosion-Proof GradeEx d IIB T4 (100% Copper)
Flexible Duct Options5m / 10m / 15m / 20m
▪Ex d IIB T4 Pure Copper Motor: Flameproof motor enclosure with 100% copper stator windings, dual-frequency 50/60 Hz compatibility, and external Ex rotary switch.
▪Ex-Proof & Standard Variants: Available in Explosion-Proof configuration (terminal wiring chamber without pre-attached cord) and Standard configuration (with power cord).
▪Confined Space Ready: Flared bellmouth casing with carry handle, anti-vibration rubber feet, and optional 5m–20m retractable PVC ventilation ducting.
Bulk & Project Supply: Specify your required fan size (200–500mm), voltage (110V/220V/380V), and flexible duct length for an immediate factory quotation.
GORNOVENT Hazardous Area & Confined Space Ventilation

Portable Explosion-Proof Axial Fan (Models 200 – 500)

GORNOVENT Portable Explosion-Proof Axial Fans are rugged, high-velocity portable ventilators engineered for rapid gas extraction, welding fume removal, and positive-pressure fresh air delivery in confined spaces and hazardous environments. Powered by a certified Ex d IIB T4 flameproof motor with 100% pure copper windings, the series operates reliably across 50/60 Hz power grids.

Covering six standard sizes from Model 200 (190 mm blade) to Model 500 (490 mm blade), these portable blowers deliver airflow from 1,500 to 10,000 m³/h and high static pressure up to 800 Pa—enabling long-distance air transfer through 5m, 10m, 15m, or 20m flexible ventilation ducts.

Ex d IIB T4 Flameproof Motor
100% Pure Copper Winding
Airflow: 1,500 – 10,000 m³/h
5m / 10m / 15m / 20m Duct Compatible
Ex d IIB T4 Copper Motor

Equipped with a cast flameproof motor enclosure and 100% pure copper stator coils for low temperature rise, continuous duty, and ignition-free safety in explosive gas atmospheres.

High Static Pressure (Up to 800 Pa)

Aerodynamic axial impeller and flared bellmouth housing generate strong static pressure to overcome friction losses in long, multi-bend flexible duct runs.

Portable & Field-Ready Build

Features an insulated top carry handle, heavy-gauge flared steel drum, front/rear finger safety guards, and four anti-vibration rubber base feet for stable floor placement.

Technical Specifications

Portable Axial Fan Performance Parameters (Models 200 – 500)

Both Explosion-Proof (Ex d IIB T4) and Standard Portable models share the aerodynamic performance parameters listed below. Dual-frequency 50/60 Hz motors are available in single-phase (110V/220V) or three-phase (380V/400V) configurations.

Model Impeller Dia. (mm) Airflow Range (m³/h) Static Pressure (Pa) Rotational Speed (r/min) Frequency (Hz) Motor Power (kW)
Model 200 190 1,500 – 2,100 250 – 420 2800 50 / 60 0.15
Model 250 240 2,700 – 3,300 300 – 450 2800 50 / 60 0.25
Model 300 290 3,300 – 3,720 350 – 500 2800 50 / 60 0.37
Model 350 340 4,840 – 5,840 550 – 600 2800 50 / 60 0.55
Model 400 390 5,860 – 6,840 750 – 800 2800 50 / 60 0.90
Model 500 490 6,800 – 10,000 185 – 200 1450 50 / 60 0.75
* Models 200–400 operate at 2800 r/min (2-pole high-pressure design for long ducting); Model 500 operates at 1450 r/min (4-pole high-volume, low-noise design for rapid air exchange).
Model Configurations

Explosion-Proof vs. Standard Configuration Comparison

To comply with hazardous-area electrical safety regulations, the Explosion-Proof version and the Standard version differ in their switch assembly and power cable delivery:

1. Explosion-Proof VersionEx d IIB T4 • Hazardous
GORNOVENT Portable Explosion-Proof Axial Fan (Ex d IIB T4)
Side Ex Rotary Switch • Supplied Without Power Cord
Motor RatingEx d IIB T4 Flameproof (100% Copper)
Switch DesignSide-Mounted Cast Ex Rotary Switch
Power Cord SupplySupplied WITHOUT Pre-Attached Cord*
Wiring MethodDirect hardwiring via Ex cable gland
Target ApplicationZone 1 & Zone 2 flammable gas & vapor
2. Standard Industrial VersionStandard • Non-Hazardous
GORNOVENT Standard Portable Industrial Axial Fan
Handle Push Switch • Supplied With Power Cord
Motor RatingStandard Industrial Duty (100% Copper)
Switch DesignHandle-Integrated Push/Toggle Switch
Power Cord SupplySupplied WITH Pre-Attached Power Cord
Wiring MethodPlug-and-play portable power cable
Target ApplicationWorkshops, civil tunnels & utility vaults
* Engineering Safety Note: In accordance with industrial explosion-protection standards, the Ex-proof model is shipped without a loose domestic power cord so site electricians can wire certified explosion-proof armored cables or Ex plugs matching local hazardous-zone regulations. Custom pre-wired Ex cables/plugs can be provided upon special request.
Confined Space Ducting

Flexible Ventilation Duct Integration (5m – 20m)

The flared outlet lip and integrated tie-cord collar allow rapid attachment of retractable PVC flexible ducting for positive-pressure blowing or negative-pressure extraction in restricted spaces.

5 MetersShort-run manhole & tank entry ventilation
10 MetersStandard utility vault & cabin exhaust
15 MetersDeep subterranean pipe gallery air supply
20 MetersLong-distance confined space fume extraction
Technical Summary

Construction & Electrical Specification Matrix

Explosion-Proof MarkEx d IIB T4 (Flameproof Enclosure)
Motor Stator Winding100% Pure Copper Coil (High Thermal Stability)
Available Sizes200 / 250 / 300 / 350 / 400 / 500 mm
Voltage Options110V / 220V (Single-Phase) or 380V / 400V / 440V (3-Phase)
Rated Frequency50 Hz / 60 Hz Dual-Frequency Compatible
Casing & CoatingFlared Steel Drum with Anti-Static Powder Coating
Safety ProtectionDual Galvanized Wire Mesh Finger Guards + Rubber Feet
Optional Accessories5m / 10m / 15m / 20m Flame-Retardant Anti-Static Duct
Selection Guide

How to Select the Right Portable Axial Ventilator

01
Determine Hazardous vs. Non-Hazardous EnvironmentChoose the Ex d IIB T4 Explosion-Proof model for oil & gas tanks, chemical plants, paint booths, and ship holds; select the Standard model for general construction and workshop cooling.
02
Match Fan Diameter to Air Volume & Duct LengthFor 5m–10m ducts in manholes, Models 200–300 (1,500–3,720 m³/h) are lightweight and ideal. For 15m–20m long duct runs requiring high static pressure (550–800 Pa), select Model 350 or Model 400. For high-volume open purging up to 10,000 m³/h, choose Model 500.
03
Confirm Site Voltage & PhaseSpecify whether your field power supply requires 110V/220V single-phase or 380V/400V/440V three-phase (50/60 Hz).
04
Specify Flexible Duct Length (5m / 10m / 15m / 20m)Order matching diameter collapsible PVC ducting with fast-cinch cuff straps and integrated suspension hooks.
Knowledge Base

Frequently Asked Questions

Why does the Explosion-Proof model come without a pre-attached power cord?

In classified hazardous areas (Zone 1 / Zone 2), safety codes prohibit standard domestic plugs and unarmored cords. The Ex-proof fan is equipped with an explosion-proof terminal chamber and side rotary switch so certified site electricians can hardwire armored cables or install region-specific explosion-proof plugs. Pre-wired Ex cables can also be customized upon order.

What does the Ex d IIB T4 explosion-proof rating mean?

Ex d indicates a flameproof enclosure capable of containing an internal explosion without igniting surrounding gases; IIB covers ethylene and common industrial petrochemical gases/vapors; T4 ensures the maximum motor surface temperature never exceeds 135°C.

Can this portable fan be used for both blowing fresh air and exhausting fumes?

Yes. By attaching the flexible duct to the outlet side, the fan delivers positive-pressure fresh air into confined spaces. By connecting the duct to the inlet side, it operates as a negative-pressure extractor to pull welding smoke, volatile vapors, or dust out of tanks and tunnels.

What lengths of flexible ventilation ducting can be connected?

We supply matching flame-retardant, wear-resistant flexible ducts in standard lengths of 5m, 10m, 15m, and 20m. For 15m and 20m runs, we recommend Models 350 or 400 (550–800 Pa static pressure) to maintain strong airflow at the duct discharge.

Request Portable Explosion-Proof Fan Pricing & Specs

Contact our sales engineering team with your model size (200–500), quantity, site voltage, and flexible duct length requirements for an immediate factory quote.