Centrifugal Roof Fan Overview
GORNOVENT supplies centrifugal roof fans for industrial and commercial
exhaust ventilation systems. The product range includes standard
centrifugal roof fans and high-pressure centrifugal roof fans,
covering different airflow and pressure requirements.
Designed for roof-mounted air extraction, these fans can be considered
for workshops, warehouses, production buildings and other facilities
requiring mechanical exhaust ventilation. Model selection depends on
the required airflow, system resistance, installation dimensions
and operating conditions.
GORNOVENT offers two centrifugal roof fan series:
- Standard centrifugal roof fans: for general roof exhaust ventilation requirements.
- High-pressure centrifugal roof fans: for ventilation systems requiring higher pressure.
Both series have separate performance and dimensional data. The correct model should be selected according to the required airflow and pressure at the same operating point.
Centrifugal Roof Fan Product Range
The two product series have different aerodynamic performance characteristics
and installation dimensions. Review the relevant performance table and
dimensional drawing before selecting a model.
Standard Centrifugal Roof Fans
The standard series is intended for general roof exhaust ventilation. It includes multiple impeller sizes, rotational speeds and motor power configurations.
Model selection should be based on the required airflow, system resistance and available installation space.
High-Pressure Centrifugal Roof Fans
The high-pressure series is intended for ventilation systems with higher pressure requirements. Its technical data provides multiple airflow and pressure operating points.
The selected model must be checked against the system duty point and the corresponding installation dimensions.
1. Standard Centrifugal Roof Fans
The standard centrifugal roof fan series covers multiple impeller sizes
and rotational speeds. The following tables provide the available
performance and dimensional specifications.

Standard Series Performance Data
The table below lists the available airflow, pressure, rotational speed, motor power and weight for each configuration.
| Model | Speed (rpm) | Airflow (m³/h) | Static Pressure (Pa) | Motor Power (kW) | Weight (kg) |
|---|---|---|---|---|---|
| 2.8 | 1440 | 1260 / 1040 | 100 / 150 | 0.18 | 18 |
| 2.8 | 2880 | 3080 / 2710 / 2300 | 100 / 300 / 500 | 0.55 | 20 |
| 3.15 | 1440 | 2050 / 1740 / 1450 | 80 / 150 / 200 | 0.18 | 19 |
| 3.15 | 2880 | 4370 / 3920 / 3470 | 150 / 400 / 600 | 1.1 | 24 |
| 3.55 | 1440 | 2880 / 2620 / 2320 | 100 / 150 / 200 | 0.25 | 21 |
| 3.55 | 2880 | 6270 / 5760 / 4930 | 150 / 400 / 700 | 2.2 | 29 |
| 4.0 | 960 | 2750 / 2590 / 2040 | 80 / 100 / 150 | 0.18 | 32 |
| 4.0 | 1440 | 4460 / 4030 / 3420 | 100 / 200 / 300 | 0.55 | 35 |
| 4.5 | 960 | 3940 / 3460 / 2760 | 100 / 150 / 200 | 0.25 | 34 |
| 4.5 | 1440 | 6280 / 5470 / 4680 | 150 / 300 / 400 | 1.1 | 39 |
| 5.0 | 720 | 4230 / 3870 / 2450 | 80 / 100 / 150 | 0.18 | 46 |
| 5.0 | 960 | 6120 / 5530 / 4470 | 100 / 150 / 200 | 0.55 | 46 |
| 5.0 | 1440 | 9650 / 8640 / 7740 | 150 / 300 / 400 | 1.5 | 52 |
| 5.6 | 720 | 4860 / 1800 | 150 / 200 | 0.37 | 67 |
| 5.6 | 960 | 9040 / 8460 / 7800 | 100 / 150 / 200 | 0.75 | 67 |
| 5.6 | 1440 | 14040 / 12960 / 11160 | 150 / 300 / 500 | 3.0 | 77 |
| 6.3 | 720 | 9090 / 7920 / 6210 | 100 / 150 / 200 | 0.75 | 80 |
| 6.3 | 960 | 12450 / 11760 / 9840 | 150 / 200 / 300 | 1.5 | 83 |
| 6.3 | 1440 | 20020 / 18970 / 17100 | 150 / 300 / 500 | 5.5 | 85 |
| 7.1 | 720 | 13800 / 12600 / 11400 | 100 / 150 / 200 | 1.1 | 96 |
| 7.1 | 960 | 17640 / 16170 / 14700 | 150 / 200 / 300 | 2.2 | 98 |
| 7.1 | 1440 | 27000 / 25400 / 24000 | 200 / 300 / 500 | 5.5 | 136 |
| 8.0 | 720 | 19800 / 18000 / 17200 | 100 / 150 / 200 | 2.2 | 146 |
| 8.0 | 960 | 26000 / 25020 / 24000 | 150 / 200 / 300 | 4.0 | 152 |
| 8.0 | 1440 | 40000 / 37800 / 35800 | 200 / 300 / 500 | 7.5 | 163 |
Note: Airflow and pressure values are listed in the corresponding sequence provided in the technical data. Confirm the required operating point against the approved fan performance curve before final selection.
Standard Series Dimensions
The following table provides the dimensional specifications of standard centrifugal roof fan models. All dimensions are in millimetres (mm).
| Model | D1 (mm) | D2 (mm) | H (mm) | H1 (mm) | Base A × A (mm) |
|---|---|---|---|---|---|
| 3 | 310 | 690 | 700 | 80 | 430 |
| 3.5 | 360 | 800 | 720 | 80 | 480 |
| 4 | 410 | 920 | 930 | 80 | 520 |
| 4.5 | 460 | 920 | 940 | 80 | 570 |
| 5 | 510 | 1000 | 980 | 80 | 640 |
| 6 | 610 | 1200 | 1070 | 80 | 820 |
| 7 | 710 | 1460 | 1290 | 80 | 910 |
| 8 | 810 | 1610 | 1370 | 80 | 1050 |
| 10 | 1010 | 1840 | 1560 | 80 | 1300 |
Please verify the roof opening, mounting interface and overall clearance against the relevant dimensional drawing before installation.
2. High-Pressure Centrifugal Roof Fans
The high-pressure centrifugal roof fan series is intended for ventilation
systems with higher pressure requirements. The available performance data
covers models from 3 to 10, while the supplied dimensional drawing covers
models from 2.8 to 8.0.

High-Pressure Series Performance Data
The following table lists the available performance points for each model. Each airflow value is paired with the pressure value in the same position.
| Model | Speed (rpm) | Airflow (m³/h) | Static Pressure (Pa) | Motor Power (kW) | Noise Level dB(A) | Weight (kg) |
|---|---|---|---|---|---|---|
| 3 | 1450 | 878 / 925 / 1059 / 1130 / 1253 | 220 / 210 / 188 / 167 / 122 | 0.75 | ≤57 | 88 |
| 3.5 | 1450 | 1395 / 1470 / 1682 / 1794 / 1990 | 299 / 285 / 256 / 227 / 166 | 1.1 | ≤59 | 95 |
| 4 | 1450 | 1887 / 2083 / 2194 / 2510 / 2677 | 412 / 391 / 372 / 334 / 298 | 1.1 | ≤62 | 115 |
| 4.5 | 1450 | 2966 / 3124 / 3574 / 3812 / 4514 | 495 / 471 / 423 / 376 / 231 | 1.1 | ≤63 | 154 |
| 5 | 1450 | 4068 / 4285 / 4903 / 5438 / 6113 | 615 / 582 / 522 / 485 / 378 | 2.2 | ≤64 | 195 |
| 6 | 960 | 5024 / 5512 / 6120 / 6782 / 7338 | 385 / 367 / 330 / 293 / 223 | 1.5 | ≤65 | 234 |
| 7 | 960 | 8015 / 8804 / 9827 / 10836 / 11925 | 548 / 499 / 448 / 398 / 371 | 3.0 | ≤68 | 292 |
| 8 | 960 | 12563 / 13565 / 14157 / 15824 / 16708 | 721 / 686 / 654 / 587 / 521 | 5.5 | ≤70 | 374 |
| 10 | 720 | 22150 / 23298 / 26573 / 28395 / 31436 | 1072 / 1020 / 916 / 813 / 702 | 7.5 | ≤72 | 396 |
Important: Each airflow value corresponds to the pressure value in the same position in the row. These values represent paired operating points, not independent airflow and pressure ranges. Confirm the required duty point against the approved fan performance curve.
High-Pressure Series Dimensions
The following dimensional data is transcribed from the supplied high-pressure series drawing. Models within the same group share the same listed dimensions. All dimensions are in millimetres (mm).
| Model | D1 (mm) | D2 (mm) | H (mm) | H1 (mm) | Base A × A (mm) | B (mm) |
|---|---|---|---|---|---|---|
| 2.8 | 500 | 690 | 615 | 50 | 605 | 370 |
| 3.15 | 500 | 690 | 615 | 50 | 605 | 370 |
| 3.55 | 500 | 690 | 615 | 50 | 605 | 370 |
| 4.0 | 700 | 935 | 722 | 50 | 880 | 645 |
| 4.5 | 700 | 935 | 722 | 50 | 880 | 645 |
| 5.0 | 700 | 935 | 722 | 50 | 880 | 645 |
| 5.6 | 800 | 1135 | 935 | 50 | 1170 | 935 |
| 6.3 | 800 | 1135 | 935 | 50 | 1170 | 935 |
| 7.1 | 970 | 1380 | 1135 | 50 | 1415 | 1185 |
| 8.0 | 970 | 1380 | 1135 | 50 | 1415 | 1185 |
The supplied dimensional drawing does not include model 10. Please request the corresponding drawing if model 10 is required. Do not use another model’s dimensions as a substitute without technical confirmation.
High-Pressure Series Dimensional Drawing
The drawing below shows the overall dimensions of the high-pressure centrifugal roof fan. Refer to the dimensional table and verify the mounting dimensions of the selected model before installation.

Typical Applications of Centrifugal Roof Fans
Centrifugal roof fans are used in mechanical exhaust ventilation systems where air is discharged through a roof-mounted fan assembly. The suitable configuration depends on the air volume, system resistance and air conditions.
Industrial Workshops
Exhaust ventilation for manufacturing workshops, production areas and industrial buildings.
Warehouses and Logistics Facilities
Roof-mounted exhaust ventilation for warehouses, storage buildings and logistics facilities.
Commercial Buildings
General exhaust ventilation for suitable commercial and public building ventilation systems.
Industrial Exhaust Systems
Air extraction applications where the fan must overcome resistance from ducts, bends, filters or other system components, subject to the selected fan’s performance capability.
How to Select the Right Centrifugal Roof Fan
A centrifugal roof fan should not be selected by model number or maximum airflow alone. The selected fan must meet the required airflow at the corresponding system pressure. Installation dimensions and operating conditions must also be checked.
1. Required Airflow
Specify the required air volume in m³/h. If the ventilation system operates under different conditions, provide the airflow required for each operating mode.
2. Required Static Pressure
Provide the estimated system resistance, including ductwork, bends, filters, dampers and other ventilation components. The fan must deliver the required airflow at the corresponding pressure.
3. Installation Dimensions
Check the roof opening, mounting base dimensions, overall height and available installation space. Use the dimensional drawing for the selected series to verify the interface dimensions.
4. Motor and Electrical Requirements
Confirm the supply voltage, frequency, number of phases, motor power and any requirements for speed control. If a variable frequency drive is required, specify the intended operating speed range.
5. Air and Operating Conditions
Provide the air temperature, dust content, humidity, corrosive characteristics and expected operating hours. These factors may affect the material selection, motor configuration and fan design.
- Required airflow (m³/h)
- Required static pressure (Pa)
- Air temperature and medium characteristics
- Power supply voltage and frequency
- Installation dimensions or roof opening drawing
- Quantity and intended application
- Any special material, control or environmental requirements
Standard vs. High-Pressure Centrifugal Roof Fans
Both series are centrifugal roof fans, but they have separate performance and dimensional specifications. The following comparison helps identify which technical data should be reviewed for a project.
| Comparison | Standard Series | High-Pressure Series |
|---|---|---|
| Intended application | General roof exhaust ventilation | Ventilation requiring higher pressure |
| Performance models in supplied data | 2.8–8.0 | 3–10 |
| Dimensional models in supplied data | 3–10 | 2.8–8.0 |
| Dimensional parameters | D1, D2, H, H1, Base A × A | D1, D2, H, H1, Base A × A, B |
| Selection basis | Airflow, pressure and installation dimensions | Airflow, pressure and installation dimensions |
The performance and dimensional tables refer to their respective product series. Do not use the dimensional data of one series to install the other series.
Industrial Fan Supply and Technical Support by GORNOVENT
GORNOVENT supplies industrial ventilation equipment for international customers and project applications. For centrifugal roof fan inquiries, we review the specified airflow, pressure, electrical requirements and installation dimensions before preparing a technical and commercial proposal.
- Technical requirement review: Evaluation of airflow, pressure and operating conditions.
- Multiple product configurations: Standard and high-pressure centrifugal roof fan options.
- Project-based quotations: Proposals based on the customer’s technical specifications.
- Dimensional information: Available dimensional data for model and installation verification.
- Export supply support: Communication and technical coordination for international projects.
Frequently Asked Questions
What is a centrifugal roof fan?
A centrifugal roof fan is a roof-mounted ventilation fan that uses a centrifugal impeller to move air through an exhaust ventilation system. It is used in suitable industrial and commercial buildings to discharge indoor air through the roof.
What is the difference between standard and high-pressure roof fans?
The two series have different aerodynamic performance ranges and dimensional configurations. Standard models are intended for general roof exhaust applications, while high-pressure models are designed for systems requiring higher pressure. Selection must be based on the required airflow and pressure at the same operating point.
How do I choose the correct centrifugal roof fan model?
Provide the required airflow, pressure, air temperature, electrical supply and installation dimensions. The fan should be selected according to the system duty point and checked against the relevant performance curve.
Can GORNOVENT provide roof fan dimensional drawings?
Dimensional information is available for the models listed in the technical tables. Contact GORNOVENT if you need a specific model drawing or confirmation of mounting dimensions before installation.
Are standard and high-pressure roof fan dimensions interchangeable?
No. The two series have separate dimensional specifications. Always refer to the drawing for the exact series and model being selected.
What information is required for a quotation?
The main requirements are airflow and pressure. Please also provide the air medium, temperature, power supply, quantity and installation dimensions where available. A fan nameplate or existing equipment drawing can also help with technical evaluation.
Request a Centrifugal Roof Fan Quotation
Looking for a standard or high-pressure centrifugal roof fan for your ventilation project? Send GORNOVENT your required airflow, pressure, operating conditions and installation requirements.
Our team can review your specifications and provide a suitable technical proposal for further evaluation. You can also attach an existing fan nameplate, performance requirement or installation drawing.